Infrared heating panel running costs

Work out what a panel costs to run using its wattage, your electricity tariff and how long it actually heats.

How much does an infrared panel heater cost per hour?

For a panel running continuously at its rated output, multiply its power in kilowatts by your electricity unit price. A 600 W panel uses 0.6 kWh in one full-power hour. At an illustrative 25p per kWh, that costs 15p.

Cost (£) = power (W) ÷ 1,000 × full-power hours × unit rate (£/kWh)

Use the unit rate on your own bill. The 25p rate below is an example, not a current tariff quotation.

Example infrared panel running costs

Illustrative electricity cost at 25p/kWh, continuously at rated output
Panel output One hour Six hours
300 W 7.5p 45p
600 W 15p 90p
900 W 22.5p £1.35
1,200 W 30p £1.80

These are arithmetic examples, not a prediction of your room’s heating demand. They exclude the household standing charge and other appliances. Equipment and installation costs are separate.

Switched on does not mean heating continuously

A thermostat can switch the heating element off when its temperature target is reached and back on as needed. Six hours scheduled is therefore not necessarily six hours at full power.

For example, a 600 W panel energised for half of a six-hour period uses 1.8 kWh, costing 45p at the example rate. That 50% operating time is an illustration, not an assumed saving: a cold or poorly insulated room may need much longer operation.

What changes the running cost in a home?

  • Heat loss: insulation, glazing, draughts and outdoor conditions affect demand.
  • Temperature and schedule: the warmth you want and hours of use affect consumption.
  • Panel placement and sizing: output and unobstructed coverage must suit the room.
  • Controls: suitable thermostats and separate room schedules help match heating to use.
  • Your tariff: use the rate applying when the heater runs; split the calculation where rates vary.

For several heaters, add their energy use. Two 600 W panels operating continuously for one hour use 1.2 kWh together. A lower-wattage heater costs less per full-power hour but may need to run longer or may not meet the room’s needs.

Is infrared cheaper than other electric heating?

Infrared can provide direct warmth in occupied areas. Whether that reduces your bill depends on the building, controls and how you use the heating. A different heating experience does not establish a fixed percentage saving.

Compare actual kWh and tariffs alongside comfort. Storage heaters may use cheaper off-peak electricity; heat pumps work differently by moving heat into the building. Read our comparison of heating options before changing a whole-home system.

Estimate the heater output, then review the costs

Our infrared heater calculator helps estimate room output and compare eligible equipment. A sizing estimate is not a measured annual energy requirement. For a bill forecast, combine suitable sizing with your tariff and a realistic operating schedule, then check actual consumption once installed.

Estimate your room Ask us to review your heating

Independent background: Energy Saving Trust: infrared heating explained and Centre for Sustainable Energy: electric heating. Examples calculated using the stated assumptions. Reviewed October 2026.

Electricity tariffs and wider heating choices

For a broader explanation of unit rates, off-peak electricity and how to compare heating options, read Elsco’s electric heating running costs and tariffs guide.

Cost per service, meeting or hall booking

For an event, add the output of the heaters in use and count the full-power operating time, including any warm-up period. For example, a 12 kW zone operating continuously for two hours uses 24 kWh and costs £6 at the illustrative 25p/kWh rate. This is not a church-sizing recommendation or a forecast for your building.

Allow separately for other zones, background heating and other electrical use. Where controls cycle the heaters, measured consumption is more useful than assuming they run at full power throughout. Our church and hall guidance explains the practical context.

Read how controls and zoning affect operation →